Arctic Materials

Technical Data Sheet

Arclear 2G

A two-component gloss overprint varnish that cross-links once the hardener is mixed in, for printed packs that meet solvents, cleaning agents, fragrances or aggressive fillings. It is a finishing layer for paper, board and film on flexo or gravure lines and is not intended as a lamination surface.

Grade Arclear 2G  |  Range Speciality Coatings for Packaging  |  Technology Two-component cross-linking gloss varnish, solvent-borne or water-based

Arctic Materials

Technical Data Sheet
Arclear 2G
Issue 2026.09

1. Product description

A two-component gloss overprint varnish that cross-links once the hardener is mixed in, for printed packs that meet solvents, cleaning agents, fragrances or aggressive fillings. It is a finishing layer for paper, board and film on flexo or gravure lines and is not intended as a lamination surface.

2. Features

  • Cross-linked gloss film resisting solvents, cleaning agents, fragrances and aggressive fillings
  • Supplied as a resin base and a separate hardener, mixed to the stated ratio before use
  • Runs on flexo and gravure coating stations with adequate drying capacity
  • Resistance continues to build for several days after the film is touch dry
  • Finishing layer only; the cured film gives a laminating adhesive little to key to

3. Recommended uses

Gloss outer finish on printed cartons, labels and film packs for household cleaners, personal care, fragrance and similar products that can wet or spill onto the printed face. Where resistance to a named product formulation is the starting point rather than the finish, Arcresist CR is the grade to begin from.

4. Typical properties

PropertyTypical valueMethod
TechnologyTwo-component cross-linking gloss varnish, solvent-borne or water-basedFormulation
AppearanceClear liquid, drying to a clear gloss filmvisual
CarrierOrganic solvent blend or water, stated for the grade supplied and matched to the ink systemformulation
Non-volatile content, mixed varnish30 to 45 per cent by weightISO 3251
Viscosity of the mixed varnish, ISO flow cup 4 mm at 23 degrees Celsius30 to 60 s at applicationISO 2431
Pot life of the mixed varnish at 23 degrees Celsius4 to 8 hours; shorter in a warm press hallISO 9514
Specular gloss at 60 degrees, on smooth coated board70 to 90 gloss units; lower on absorbent or uncoated stockISO 2813
Solvent resistance of the cured filmNo break-through with the agreed solvent at the agreed number of double rubs, tested after full cureASTM D5402
Development of full resistance3 to 7 days at 20 to 25 degrees Celsius after coatingcustomer or supplier protocol, solvent rub on conditioned samples

Typical values, not a specification. Values for each batch are given on its Certificate of Analysis.

5. Application

ParameterGuidance
Application methodFlexo coating station with anilox roll and chambered doctor blade, or gravure coating cylinder; full web or spot
Surface preparationInk fully dried before coating. On polyolefin film, check wetting tension on the reel to be coated with the test solutions of ASTM D2578. Trial over the printed areas, not on the unprinted edge of the web. Keep carton glue laps and any area to be laminated uncoated
MixingAdd the hardener to the base at the ratio stated on the label, stir thoroughly and use within the pot life; do not return mixed varnish to the base container
DilutionSupplied at or near application strength; reduce only with the diluent specified by Arctic for the grade, check flow time to ISO 2431 at fixed intervals recorded against temperature, and confirm any correction against a measured coat weight
Applied dry coat weight1.5 to 3.0 g/m2, raised over heavy ink coverage
Drying and cureDryer air typically 50 to 80 degrees Celsius, limited by the heat tolerance of the substrate, set so the web leaves dry, free of retained solvent and cool at the rewind; water-based grades need more drying energy and dwell than solvent-borne grades at the same coat weight. Allow 3 to 7 days at 20 to 25 degrees Celsius before tight stacking, filling or resistance testing
Clean-upClean anilox rolls, chambers and pans before mixed varnish sets in them, using the cleaning solvent specified for the grade

6. Storage and handling

Store the base and the hardener in their original containers, kept closed, in a cool, dry, covered area away from direct sunlight and sources of heat, within the temperature range given on the label; keep the hardener sealed against moisture and protect water-based grades from frost. Shelf life is stated on the label and on the Certificate of Analysis. Handle and use the product in line with its Safety Data Sheet.

7. Safety and regulatory information

Read the Safety Data Sheet before use. Safety Data Sheets and regulatory declarations are issued by our technical centre against the product and batch supplied, so they are sent on request rather than published. Request a Safety Data Sheet or declaration.

This Technical Data Sheet is published for on-screen reference. The information is given in good faith from laboratory and application experience and describes typical values; it is not a specification and does not replace a trial on your own substrate and line. Arctic Materials may revise this sheet without notice. Issue 2026.09.

Technical Data Sheets on this site are for on-screen viewing. For a controlled copy, write to tech@arcticmaterials.com.