Arctic Materials

Technical Data Sheet

Arccoil PV 550 PVDF Metallic Coil System, Three Coat

A three-coat PVDF coil system of primer, metallic or mica pigmented basecoat and a clear fluoropolymer top layer, for metallic and pearlescent architectural finishes. The clear layer protects the effect pigment and helps hold an even orientation, which a two-coat film would not.

Grade Arccoil PV 550  |  Range Coil and Extrusion Coatings  |  Technology Solvent-borne three-coat PVDF system with a clear fluoropolymer top layer

Arctic Materials

Technical Data Sheet
Arccoil PV 550
Issue 2026.09

1. Product description

A three-coat PVDF system of primer, metallic or mica pigmented basecoat and a clear fluoropolymer top layer, for metallic and pearlescent architectural finishes where a two-coat film would not protect the effect pigment or hold an even orientation. Total film build is higher than Arccoil PV 510 and, on a conventional two-coater line, the coil has to run twice, which roughly halves effective output. Metallic finishes are directional, so panel orientation has to be fixed on the drawing and carried through fabrication and installation.

2. Features

  • Three coats: primer, metallic or mica pigmented basecoat, clear fluoropolymer top layer
  • Clear layer protects the effect pigment
  • Higher total film build than Arccoil PV 510
  • Directional finish: panel orientation is fixed on the drawing and carried through fabrication and installation
  • Runs in two passes on a conventional two-coater line

3. Recommended uses

Metallic and pearlescent finishes on architectural cladding, rainscreen and curtain wall. Supplied on primed aluminium strip, and on primed steel strip where the specification allows it.

Substrates. Primed aluminium strip, and primed steel strip where the specification allows it.

4. Typical properties

PropertyTypical valueMethod
TechnologySolvent-borne three-coat PVDF system with a clear fluoropolymer top layerFormulation
Dry film thicknessPrimer 5 to 8 microns; basecoat nominally 20 microns, inside the 18 to 25 micron topcoat window; clear coat 10 to 15 micronsEN 13523-1; ASTM D7091 for the magnetic induction or eddy current check on the line
Peak metal temperature at oven exit232 to 249 degrees Celsius in each oven sectionStrip-attached thermocouple or peak metal temperature recorder read on the line; a line measurement, as there is no dedicated published test standard
Specular gloss, 60 degrees25 to 40 gloss unitsISO 2813, ASTM D523, EN 13523-2
Colour and effect against the approved panelTolerance and viewing geometry agreed separately, because a single Delta E does not describe an effect finishCustomer or supplier protocol, agreed on approved panels
T-bend flexibility on 0.5 mm strip, no cracking with a tape pull across the bend0T to 1T, with the higher total film build of the three-coat system tending toward the 1T end; confirm against the actual forming scheduleEN 13523-7, ASTM D4145
Pencil hardnessHB to F, as the fluoropolymer film is soft by designEN 13523-4, ASTM D3363
Solvent resistance, methyl ethyl ketone double rubs50 to 100 double rubs on the clear coat without breakthrough to the basecoat, used as a cure check on the line; check the first-pass basecoat the same way, without exposure of the primer, before the second passEN 13523-11, ASTM D5402
Accelerated ultraviolet exposure, UV-A 340 lamps with condensation1000 to 2000 hours, with gloss retention and colour change agreed for the grade; cabinet hours rank systems and do not convert into years in serviceEN 13523-10, ISO 16474-3, ASTM G154
Neutral salt spray resistance, finished system500 to 1000 hours with creep from the scribe not more than 2 mm and no field blistering, set by the system chemistry and film buildISO 9227, ASTM B117, EN 13523-8

Typical values, not a specification. Values for each batch are given on its Certificate of Analysis.

5. Application

ParameterGuidance
Application methodRoll coating in two passes on a two-coater line
Surface preparationStrip cleaned, rinsed, chemically pretreated and dried on the line; a clean, correctly weighted conversion coating is required, as no primer recovers a contaminated or under-treated strip
First passPrimer at 5 to 8 microns and basecoat at nominally 20 microns dry, held inside the 18 to 25 micron topcoat window, each oven section run to 232 to 249 degrees Celsius peak metal temperature and quenched
Second passClear coat at 10 to 15 microns dry, cured to 232 to 249 degrees Celsius peak metal temperature and quenched
Viscosity adjustmentHold the supply at the agreed viscosity and coater temperature; correct with the supplied thinner only, to the supplied ratio
Line outputRunning the coil twice roughly halves effective output on a conventional two-coater line
Panel orientationFix orientation on the drawing and carry it through fabrication and installation, as metallic finishes are directional

Process. Roll coated in two passes on a two-coater line: primer at five to eight microns and basecoat at nominally twenty microns in the first pass, clear coat at ten to fifteen microns in the second. Each oven section is run to a peak metal temperature of 232 to 249 degrees Celsius and the strip is quenched after each.

6. Storage and handling

Store each component in the original, tightly closed containers in a cool, dry, covered area away from direct sunlight and heat, and stir to a uniform consistency before use. Shelf life is stated on the label and Certificate of Analysis. Handle and use the product in line with its Safety Data Sheet.

7. Safety and regulatory information

Read the Safety Data Sheet before use. Safety Data Sheets and regulatory declarations are issued by our technical centre against the product and batch supplied, so they are sent on request rather than published. Request a Safety Data Sheet or declaration.

This Technical Data Sheet is published for on-screen reference. The information is given in good faith from laboratory and application experience and describes typical values; it is not a specification and does not replace a trial on your own substrate and line. Arctic Materials may revise this sheet without notice. Issue 2026.09.

Technical Data Sheets on this site are for on-screen viewing. For a controlled copy, write to tech@arcticmaterials.com.