Arctic Materials

Technical Data Sheet

Arcvolt SO 210 Anti-Soiling Front Glass Topcoat

A sub-micron hydrophobic anti-soiling topcoat for photovoltaic module front glass, intended to reduce dust adhesion and cementation in dry and dusty sites and to lengthen the interval between cleaning campaigns. Build is kept well under one micron so that the loss in visible transmission stays inside the limit agreed for the project.

Grade Arcvolt SO 210  |  Range Energy and Electronics Coatings  |  Technology Sub-micron hydrophobic topcoat for glass

Arctic Materials

Technical Data Sheet
Arcvolt SO 210
Issue 2026.09

1. Product description

A sub-micron hydrophobic anti-soiling topcoat for photovoltaic module front glass, intended to reduce dust adhesion and cementation in dry and dusty sites and to lengthen the interval between cleaning campaigns. Build is kept well under one micron so that the loss in visible transmission stays inside the limit agreed for the project, and the formulation is made to sit over anti-reflective glass without closing the porous layer. It is applied either in the module line or in the field during a cleaning campaign.

2. Features

  • Hydrophobic film, initial water contact angle 95 to 110 degrees
  • Sub-micron build of 0.1 to 1 micron dry
  • Formulated to sit over anti-reflective glass without closing the porous layer
  • Applied in the module line or in the field during a cleaning campaign

3. Recommended uses

Front glass of photovoltaic modules in dry and dusty sites, applied to new modules in the production line or to installed modules during a cleaning campaign.

Substrates. Low-iron solar glass, anti-reflective coated solar glass, polymer front sheets, glass on already-installed modules.

4. Typical properties

PropertyTypical valueMethod
TechnologySub-micron hydrophobic topcoat for glassFormulation
AppearanceTransparent film; loss in visible transmission within the limit agreed for the projectCustomer or supplier protocol
Water contact angle95 to 110 degrees initial, with the retained value after weathering stated in the project specificationASTM D7334
Applied build0.1 to 1 micron dry, held at the low end of the range on anti-reflective glass; controlled by transmission loss and applied wet volume per square metre, not by a thickness gaugeCustomer or supplier protocol
Accelerated weathering2000 to 4000 h xenon-arc exposure, with retained contact angle and transmission limits agreed for the projectISO 16474-2
Compatibility with anti-reflective glassSits over the anti-reflective layer without closing its poresCustomer or supplier protocol
Cure windowAmbient cure in 2 to 4 hours, or force cure 10 to 20 minutes at 80 to 120 degrees CCustomer or supplier protocol

Typical values, not a specification. Values for each batch are given on its Certificate of Analysis.

5. Application

ParameterGuidance
Application methodFlow, fine spray or wipe
Surface preparationGlass cleaned and dried, and free of alkaline cleaner residue
Applied build0.1 to 1 micron dry, set by applied wet volume per square metre and checked by transmission loss. On anti-reflective coated glass the build is held at the low end of the range and transmission loss is measured on the AR glass being coated.
Cure scheduleAmbient cure in 2 to 4 hours, or force cure 10 to 20 minutes at 80 to 120 degrees C in the module line
Field applicationOn installed modules, applied during a cleaning campaign after the glass has been cleaned and dried

Process. Flow, fine spray or wipe application at 0.1 to 1 micron dry on cleaned and dried glass. Ambient cure in 2 to 4 hours, or force cure 10 to 20 minutes at 80 to 120 degrees C in the module line. The surface must be free of alkaline cleaner residue before application. Build at this scale is controlled by transmission loss and by applied wet volume per square metre, not by a thickness gauge.

6. Storage and handling

Store in the original closed containers in a cool, dry, covered area, away from direct sunlight and sources of heat. Shelf life is stated on the label and Certificate of Analysis. Handle and use the product in line with its Safety Data Sheet.

7. Safety and regulatory information

Read the Safety Data Sheet before use. Safety Data Sheets and regulatory declarations are issued by our technical centre against the product and batch supplied, so they are sent on request rather than published. Request a Safety Data Sheet or declaration.

This Technical Data Sheet is published for on-screen reference. The information is given in good faith from laboratory and application experience and describes typical values; it is not a specification and does not replace a trial on your own substrate and line. Arctic Materials may revise this sheet without notice. Issue 2026.09.

Technical Data Sheets on this site are for on-screen viewing. For a controlled copy, write to tech@arcticmaterials.com.