Arctic Materials

Technical Data Sheet

Arcvolt AS 430 Conductive and Shielding Coating

A conductive coating supplied in two fills: a carbon-filled version at 1×10^2 to 1×10^4 ohms per square for grounding and charge drainage, and a nickel- or copper-filled version below 1 ohm per square for attenuating radiated fields. Attenuation follows conductivity and continuity, so a grade specified only as conductive will not shield.

Grade Arcvolt AS 430  |  Range Energy and Electronics Coatings  |  Technology Conductive coating, carbon-filled or nickel- or copper-filled

Arctic Materials

Technical Data Sheet
Arcvolt AS 430
Issue 2026.09

1. Product description

A conductive coating supplied in two fills for two different duties. The carbon-filled version sits at roughly 1×10^2 to 1×10^4 ohms per square and is used for grounded enclosure interiors, static-free faces and charge drainage. The metal-filled version, pigmented with nickel or copper, is taken below 1 ohm per square, which is the range where a coated surface begins to attenuate a radiated field; attenuation follows conductivity and continuity, so a grade specified only as conductive will not shield. In both cases contact pads, gasket lands and mating edges have to be coated and kept free of overspray from later layers, and the ground path has to be designed in.

2. Features

  • Carbon-filled version at 1×10^2 to 1×10^4 ohms per square for grounding and charge drainage
  • Nickel- or copper-filled version below 1 ohm per square for shielding
  • Applied in two to three passes at 30 to 60 microns dry
  • Ground continuity and shielding assessed on the assembled enclosure

3. Recommended uses

Carbon-filled: grounded enclosure interiors, static-free faces and charge drainage. Metal-filled: shielding of moulded thermoplastic, composite and GRP electronics housings, with the ground path designed in.

Substrates. ABS/PC blends, glass-filled polyamide and PBT, composite and GRP housings, moulded thermoplastic enclosure interiors, primed aluminium.

4. Typical properties

PropertyTypical valueMethod
TechnologyConductive coating, carbon-filled or nickel- or copper-filledFormulation
Surface resistivity, carbon-filled version1×10^2 to 1×10^4 ohms per squareCustomer or supplier protocol
Surface resistivity, metal-filled versionBelow 1 ohm per squareCustomer or supplier protocol
Shielding effectiveness, metal-filled version30 to 60 dB over 30 MHz to 1.5 GHz on a flat specimen at a surface resistivity below 1 ohm per square; performance on the assembly is assessed separatelyASTM D4935
Shielding, carbon-filled versionLimited attenuation; specified for grounding, not shieldingNot applicable
Dry film thickness30 to 60 micronsISO 2808
Adhesion, cross-cutClassification 0 to 1 on the specified pre-treatmentISO 2409
Ground continuityMeasured across the assembled enclosure, not only on a flat panelCustomer or supplier protocol
Drying windowForce dry 20 to 30 minutes at 60 to 80 degrees CCustomer or supplier protocol

Typical values, not a specification. Values for each batch are given on its Certificate of Analysis.

5. Application

ParameterGuidance
Application methodConventional or HVLP spray in two to three passes
Surface preparationClean, dry and free of release agent and dust
Before useStir to a uniform consistency so the filler is evenly dispersed, and keep the material agitated throughout spraying, in an agitated pressure pot where one is used, because the metal and carbon fillers settle
Applied film thickness30 to 60 microns dry, with edge, rib and corner coverage confirmed visually
Drying scheduleForce dry 20 to 30 minutes at 60 to 80 degrees C
Contact areasCoat contact pads, gasket lands and mating edges and keep them free of overspray from later layers; the ground path has to be designed in
VerificationMeasure ground continuity across the assembled enclosure, and assess shielding on the assembly rather than inferring it from panel resistivity

Process. Conventional or HVLP spray in two to three passes at 30 to 60 microns dry, with edge, rib and corner coverage confirmed visually. Force dry 20 to 30 minutes at 60 to 80 degrees C. Ground continuity is measured across the assembled enclosure, not only on a flat panel, and shielding performance is assessed on the assembly rather than inferred from panel resistivity.

6. Storage and handling

Store in the original closed containers in a cool, dry, covered area, away from direct sunlight and sources of heat. Shelf life is stated on the label and Certificate of Analysis. Handle and use the product in line with its Safety Data Sheet.

7. Safety and regulatory information

Read the Safety Data Sheet before use. Safety Data Sheets and regulatory declarations are issued by our technical centre against the product and batch supplied, so they are sent on request rather than published. Request a Safety Data Sheet or declaration.

This Technical Data Sheet is published for on-screen reference. The information is given in good faith from laboratory and application experience and describes typical values; it is not a specification and does not replace a trial on your own substrate and line. Arctic Materials may revise this sheet without notice. Issue 2026.09.

Technical Data Sheets on this site are for on-screen viewing. For a controlled copy, write to tech@arcticmaterials.com.