Arctic Materials

Technical Data Sheet

Arcvolt TH 430 Thermally Conductive Insulating Coating

A ceramic-filled coating applied at higher build that is electrically insulating and thermally conductive at the same time, for insulated metal panels, magnetics, bus structures and cast housings where an isolation layer sits directly in the heat path. It is specified when the insulating layer cannot be allowed to become the dominant thermal resistance.

Grade Arcvolt TH 430  |  Range Energy and Electronics Coatings  |  Technology Ceramic-filled insulating stoving coating

Arctic Materials

Technical Data Sheet
Arcvolt TH 430
Issue 2026.09

1. Product description

A ceramic-filled coating applied at higher build that is electrically insulating and thermally conductive at the same time, for insulated metal panels, magnetics, bus structures and cast housings where an isolation layer sits directly in the heat path. It is specified when the insulating layer cannot be allowed to become the dominant thermal resistance. It is a conduction path in series with the rest of the assembly and does not replace a heat sink, a fan or a redesigned airflow route.

2. Features

  • Electrically insulating and thermally conductive in one film
  • Ceramic-filled, thermal conductivity 0.5 to 2.0 W per m K
  • Applied at 80 to 200 microns dry, in two passes above 120 microns
  • Dielectric withstand proof tested at the minimum measured film thickness

3. Recommended uses

Insulated metal substrate panels, transformer and inductor bodies, copper bus and die-cast or machined aluminium housings where an isolation layer sits in the heat path. It is a conduction path in series with the assembly and does not replace a heat sink, a fan or a redesigned airflow route.

Substrates. Aluminium insulated metal substrate panels, die-cast and machined aluminium, steel, transformer and inductor bodies, copper bus.

4. Typical properties

PropertyTypical valueMethod
TechnologyCeramic-filled insulating stoving coatingFormulation
Thermal conductivity0.5 to 2.0 W per m KASTM D5470
Dielectric strength15 to 45 kV per mm depending on film build, stated at the measured minimum thicknessIEC 60243-1
Volume resistivityAbove 1×10^14 ohm cmASTM D257
Dry film thickness80 to 200 micronsISO 2808
Adhesion, pull-off3 to 8 MPa depending on substrate and pre-treatment, with cohesive rather than adhesive failure preferredISO 4624
Adhesion, cross-cutClassification 0 to 1 on the specified pre-treatmentISO 2409
Thermal cycling200 to 1000 cycles between minus 40 and plus 85 degrees C with no cracking, delamination or loss of insulation resistanceIEC 60068-2-14
Cure window25 to 40 minutes at 150 to 180 degrees C metal temperatureCustomer or supplier protocol

Typical values, not a specification. Values for each batch are given on its Certificate of Analysis.

5. Application

ParameterGuidance
Application methodSpray, flow coat or screen application
Surface preparationClean and degreased, with the pre-treatment specified for the substrate; edges and radii need attention because thin points there set the dielectric result
Applied film thickness80 to 200 microns dry, in two passes where build exceeds 120 microns
Flash offAllow each pass to flash off before the next and before stoving, so carrier is not trapped in the thick film and does not blister in the oven
Cure scheduleStove 25 to 40 minutes at 150 to 180 degrees C metal temperature
Proof testingTest dielectric withstand at the minimum measured film thickness, not at the average
Design noteThe film is a conduction path in series with the rest of the assembly and does not replace a heat sink, a fan or a redesigned airflow route

Process. Spray, flow coat or screen application at 80 to 200 microns dry, applied in two passes where build exceeds 120 microns. Stove 25 to 40 minutes at 150 to 180 degrees C metal temperature. Dielectric withstand is proof tested at the minimum measured film thickness, not at the average, because thin points at edges and radii set the result.

6. Storage and handling

Store in the original closed containers in a cool, dry, covered area, away from direct sunlight and sources of heat. Shelf life is stated on the label and Certificate of Analysis. Handle and use the product in line with its Safety Data Sheet.

7. Safety and regulatory information

Read the Safety Data Sheet before use. Safety Data Sheets and regulatory declarations are issued by our technical centre against the product and batch supplied, so they are sent on request rather than published. Request a Safety Data Sheet or declaration.

This Technical Data Sheet is published for on-screen reference. The information is given in good faith from laboratory and application experience and describes typical values; it is not a specification and does not replace a trial on your own substrate and line. Arctic Materials may revise this sheet without notice. Issue 2026.09.

Technical Data Sheets on this site are for on-screen viewing. For a controlled copy, write to tech@arcticmaterials.com.