Arctic Materials

Technical Data Sheet

Arctube ML 230 Low-Cure Monobloc Aerosol Lining

Arctube ML 230 is an internal lining for monobloc aerosol cans formulated to cure at about 190 to 215 degrees C metal temperature, below the roughly 230 to 260 degrees C of a conventional internal bake. The lower cure keeps more of the strength of the work-hardened wall and reduces oven energy.

Grade Arctube ML 230  |  Range Tube, Aerosol and Aluminium Bottle Coatings  |  Technology Solvent-borne low-cure lining, in epoxy-phenolic and BPA-NI versions

Arctic Materials

Technical Data Sheet
Arctube ML 230
Issue 2026.09

1. Product description

An internal lining for monobloc aerosol cans, formulated to cure at around 200 degrees C metal temperature instead of the roughly 230 to 260 degrees C of a conventional internal bake. The internal cure runs hotter than any other step on a monobloc line and partly anneals the work-hardened wall, so a lower cure keeps more of the alloy’s strength, which helps lightweight and harder-alloy cans hold their test pressure, and it cuts oven energy. It is directed at anhydrous fills with hydrocarbon propellant, such as deodorants and hairsprays, and is offered in epoxy-phenolic and BPA-NI versions. Run in an oven that cannot hold the lower window evenly, it under-cures and fails the solvent rub and the pack test.

2. Features

  • Cures at about 190 to 215 degrees C metal temperature
  • Helps lightweight and harder-alloy cans hold their test pressure
  • Offered in epoxy-phenolic and BPA-NI versions
  • Needs an oven that holds the lower window evenly; profiled with a logger before trial

3. Recommended uses

Internal lining of monobloc aerosol cans for anhydrous fills with hydrocarbon propellant, such as deodorants and hairsprays.

Substrates. Monobloc aerosol cans impact extruded from 1000-series aluminium or from harder alloys such as 3000-series grades, with round, flat or shaped shoulders.

4. Typical properties

PropertyTypical valueMethod
TechnologySolvent-borne low-cure lining, in epoxy-phenolic and BPA-NI versionsFormulation
CarrierOrganic solvent blendNot applicable
Non-volatile content25 to 45 per cent by weightISO 3251
Supply viscosity30 to 60 s, 4 mm flow cup at 23 degrees C, or the 3 mm cup for thinner gradesISO 2431
Dry film weight5 to 12 g/m2, reported as mg per can for the customer's sizeGravimetric, can weighed before and after stripping the cured film, supplier protocol
Cure state50 to more than 100 methyl ethyl ketone double rubs without breakthrough, according to gradeASTM D5402
AdhesionCross-cut classification 0 to 1 on flat aluminium panels; no coating removal by tape on the formed containerISO 2409 on panels; customer or supplier protocol on containers
FlexibilityNo cracking or loss of adhesion on the conical mandrel on coated aluminium panelISO 6860
Porosity of the internal filmCurrent reading within the acceptance limit agreed for the container size at qualification, read on finished, necked cans; limits are not transferable between container sizes, electrolytes or test voltagesCurrent conduction with an electrolyte fill (enamel rater), customer or industry protocol
Pack test with the actual fillNo blistering, delamination, corrosion or change in the product after storage, commonly at 40 to 50 degrees C for 1 to 6 monthsCustomer protocol, cans valved and pressurised with the actual propellant

Typical values, not a specification. Values for each batch are given on its Certificate of Analysis.

5. Application

ParameterGuidance
Application methodLance spray into the rotating can
Surface preparationCan washed or degreased to remove the extrusion lubricant before lining
Viscosity adjustmentAdjusted at the line within 30 to 60 s (ISO 2431 flow cup, 23 degrees C) to suit the spray equipment, using only the thinner Arctic specifies for the grade
Dry film weight5 to 12 g/m2, quoted as mg per can
Cure scheduleTypically 6 to 12 min at about 190 to 215 degrees C metal temperature, set against the customer's oven. The oven is profiled with a logger on cans first; an oven that cannot hold the window evenly under-cures the film
Next stepExternal basecoat such as Arctube BC 160, dry offset print and overvarnish; the can is necked after the last bake
QualificationSolvent rub on cured cans, pack test with valved and pressurised cans, and a trial on the customer's line

Process. Sprayed by lance into the rotating can, typically 5 to 12 g/m2 dry film, quoted as mg per can for the customer’s size, and cured typically 6 to 12 min at about 190 to 215 degrees C metal temperature, set against the customer’s oven. The oven is profiled with a logger on cans before a trial on the customer’s line, which is required.

6. Storage and handling

Store in the original, tightly closed containers in a cool, dry, covered area, protected from frost, direct sunlight and heat, and keep containers closed between uses to limit solvent loss. Shelf life is stated on the label and Certificate of Analysis; handling guidance is given in the Safety Data Sheet, issued on request. Handle and use the product in line with its Safety Data Sheet.

7. Safety and regulatory information

Read the Safety Data Sheet before use. Safety Data Sheets and regulatory declarations are issued by our technical centre against the product and batch supplied, so they are sent on request rather than published. Request a Safety Data Sheet or declaration.

This Technical Data Sheet is published for on-screen reference. The information is given in good faith from laboratory and application experience and describes typical values; it is not a specification and does not replace a trial on your own substrate and line. Arctic Materials may revise this sheet without notice. Issue 2026.09.

Technical Data Sheets on this site are for on-screen viewing. For a controlled copy, write to tech@arcticmaterials.com.